C406H Oxygen /Water Vapor Transmission Rate Test System is based on the testing principle of Coulometric oxygen sensor and infrared water vapor sensor. It is designed and manufactured according to ASTM D3985、ASTM F1249,ISO 15106-2 and other relevant standards to provide high precision and high efficiency oxygen and water vapor transmission rate tests for high and medium gas barrier materials. It is suitable for testing the oxygen and water vapor transmission performance of films, sheets and related materials in the fields of food, medicine, medical devices, daily chemicals, photovoltaic, electronic and many others.
The pre-treated sample is clamped between the test chambers, oxygen or nitrogen with stable relative humidity flows on one side of the film, and the high purity nitrogen flows on the other side; oxygen or water molecules diffuse through the film into high-purity nitrogen on the other side, and are carried to the sensor by the flowing nitrogen. By analyzing the oxygen or water vapor concentration measured by the sensor, the oxygen or water vapor transmission rate can be calculated.
ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015
ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015
Applications |
---|
The oxygen and water vapor transmission rate tests of various plastic films, paper-plastic composite films, co-extrusion films, aluminized films, aluminum foil composite films, glass fiber aluminum foil paper composite films and other film-like materials. |
The oxygen and water vapor transmission rate tests of PP sheet, PVC sheet, PVDC sheet, metal foil, rubber sheet, silicon sheet and other sheet materials. |
Table 1: Test Parameters Note2
Parameter/Model | Model C406H | |
---|---|---|
OTR Test Range | cc/(m2·day) (Standard area 50cm2) | 0.02 ~ 200 |
cc/(m2·day) (MASK area 1cm2) | 1 ~ 10000 (Optional) | |
cc/(m2·day) (MASK area 5cm2) | 0.2 ~ 2000 (Optional) | |
OTR Resolution | cc/(m2·day) | 0.0001 |
OTR Repeatability | cc/(m2·day) | 0.02 or 1%, whichever is greater |
WVTR Test Range | g/(m2·day) (Standard area 50cm2) | 0.02 ~ 40 |
g/(m2·day) (MASK area 5cm2) | 0.2 ~ 400 (Optional) | |
g/(m2·day) (MASK area 1cm2) | 1 ~ 2000 (Optional) | |
WVTR Resolution | g/(m2·day) | 0.0001 |
WVTR Repeatability | g/(m2·day) | 0.02 or 2%, whichever is greater |
Temperature range | °C | 15 - 50 5 – 60 (Customized) |
Temperature fluctuation | °C | ±0.15 |
Humidity range | %RH (Within standard temperature range) | 0%, 5 - 90%±2%, 100% |
Extended functions | GP-01 Gas Purification Unit | Optional |
DataShieldTM Note3 | Optional | |
Computer System required by GMP | Optional | |
CFR21 Part11 | Optional |
Table 2: Technical Specifications
Test Chamber | 6 test chambers |
Specimen Size | 4.6” x 4.6”(11.7cm×11.7cm) |
Specimen Thickness | ≤120 Mil(3mm) |
Standard Test Area | 50 cm2 |
Carrier Gas | 99.999% high purity nitrogen, 99.5% oxygen (gas source is out of supply scope) |
Carrier Gas Pressure | ≥ 40.6 PSI / 280 kPa |
Port Size | 1/8 inch metal tubing |
Power Supply | 120VAC±10% 60Hz / 220VAC±10% 50Hz(either one of two) |
Instrument Dimensions | 23.6” H x 19.2” W x 25.9” D (60cm× 49cm× 66cm) |
Net weight | 220Lbs(100kg) |
Note 1: All the product features are subject to detailed descriptions in the “Technical Parameters”.
Note 2: The parameters in the table are measured by professional operators in Labthink Laboratory according to the requirements and conditions of relevant laboratory environmental standards.
Note 3: DataShieldTM Data Shield System provides safe and reliable data application support. The system can be shared by multiple Labthink products. Please purchase separately as needed.
We can help you select or customize the proper unit for your test requirements.
Need help or have a question? For more information on how Labthink can help your company profit through testing, please Click the button.